Siemens 6AV2125-2GB03-0AX0 SIMATIC HMI KTP700 Basic
€ 922,00 – € 1.572,30Price range: € 922,00 through € 1.572,30
The Siemens 6AV2125-2GB03-0AX0 is a KTP700 Basic Panel belonging to the SIMATIC HMI Basic Panel generation 2 family. It is a 7-inch widescreen touch and key panel designed for straightforward machine-level visualization tasks. This unit is manufactured by Siemens and integrates seamlessly into the SIMATIC automation environment.
The KTP700 Basic features a 7-inch TFT widescreen display with a resolution of 800 x 480 pixels and 65,536 colors, combined with 8 configurable function keys for operator input. It communicates via a PROFINET interface (RJ45) and is configured using Siemens WinCC Basic software within the TIA Portal engineering framework. The panel operates on 24 V DC supply voltage and offers 10 MB of user memory for project data, with an operating temperature range of 0 to 50 degrees Celsius.
The KTP700 Basic Panel is widely used in machine building, packaging machinery, conveyor systems, and general factory automation where compact and cost-effective HMI solutions are required. Its PROFINET connectivity makes it suitable for direct integration with SIMATIC S7-1200 and S7-1500 PLCs. The panel's robust construction and IP65 front protection rating make it appropriate for installation in industrial control cabinets and machine panels exposed to dust and water spray.
Technical Specifications
| Display Size | 7 inch |
|---|---|
| Display Resolution | 800 x 480 pixels |
| Display Colors | 65,536 (16-bit) |
| Display Type | TFT widescreen |
| Touch Technology | Resistive touch screen with 8 function keys |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Typical 4.5 W |
| Communication Interface | PROFINET (RJ45, 10/100 Mbit/s) |
| User Memory | 10 MB |
| Operating Temperature | 0 to 50 °C |
| Storage Temperature | -20 to 60 °C |
| Relative Humidity | 10 to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Configuration Software | WinCC Basic (TIA Portal) |
| Compatible PLCs | SIMATIC S7-1200, S7-1500 |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been lost.
Check PROFINET cable and RJ45 connector integrity. Verify IP address configuration on both the HMI and PLC. Ensure the PLC is in RUN mode and the network switch or router is operational. - Event ID: 10001
- Connection to PLC interrupted during runtime. The HMI lost communication with the configured controller.
Inspect network cabling for damage or loose connections. Verify PLC is powered and running. Check for IP address conflicts on the network segment. - Event ID: 20000
- Project download error. The project could not be transferred to the HMI panel from the engineering station.
Verify the Ethernet connection between the PC and HMI. Ensure TIA Portal project is compiled without errors. Check that the correct HMI device IP address is configured in the project. - Event ID: 40000
- System memory low. Available runtime memory on the HMI panel is insufficient to load the project or a screen.
Reduce the project size by optimizing graphics and screen objects. Delete unused screens or tags. Ensure the project does not exceed the 10 MB user memory limit. - Event ID: 70010
- Tag read error. A configured tag could not be read from the PLC within the defined timeout period.
Verify the tag address exists in the PLC program and matches the HMI tag configuration. Check communication connection status. Confirm the PLC data block or memory area is accessible. - Event ID: 70011
- Tag write error. A write request from the HMI to a PLC tag failed.
Check that the target PLC tag is not write-protected. Verify the tag address and data type match between HMI configuration and PLC program. Confirm the PLC is in a state that allows write access. - Event ID: 80000
- Operating system error on the HMI panel. An internal system fault has been detected.
Perform a panel restart by cycling the 24 V DC power supply. If the fault persists, perform a factory reset and reload the project. Contact Siemens technical support if the error recurs after reset.
Frequently Asked Questions
What PLC systems are compatible with the KTP700 Basic 6AV2125-2GB03-0AX0?
The KTP700 Basic is primarily designed for use with Siemens SIMATIC S7-1200 and S7-1500 PLCs via PROFINET. It can also communicate with S7-300 and S7-400 controllers using appropriate Ethernet connections configured in TIA Portal.
What software is required to configure and program this HMI panel?
The 6AV2125-2GB03-0AX0 is configured exclusively using Siemens WinCC Basic, which is included within the TIA Portal engineering software suite. A minimum of TIA Portal V13 is required, with later versions recommended for full feature support.
What is the supply voltage for the KTP700 Basic panel?
The panel requires a 24 V DC supply voltage. It is important to use a regulated power supply that meets this specification to ensure stable operation.
Does the KTP700 Basic support USB for project transfer or data logging?
Yes, the KTP700 Basic Panel features a USB Type-A interface that can be used for project transfer via USB memory stick and for data logging or recipe export functions.
What is the front panel protection rating of the 6AV2125-2GB03-0AX0?
The front of the panel is rated IP65, providing protection against dust ingress and water jets. The rear of the unit is rated IP20, so the installation enclosure must provide adequate rear protection.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel power connector. Check polarity and verify the supply is within the acceptable voltage range. Inspect the power connector for loose or damaged pins.
Correct any wiring faults or polarity errors. Replace the power supply if the output voltage is out of specification. If supply voltage is correct and the display remains blank, the internal backlight or power board may be faulty and the panel should be sent for repair.
HMI shows 'Connecting…' or communication error on startup
Verify the PROFINET cable is securely connected to both the HMI RJ45 port and the PLC or network switch. Check the IP address settings on the HMI under the Start Center settings menu and compare with the project configuration in TIA Portal.
Correct any IP address mismatches between the HMI and the TIA Portal project. Replace the Ethernet cable if damaged. Ensure the PLC is powered and in RUN mode. Re-download the project to the HMI if configuration changes were made.
Touchscreen does not respond or responds inaccurately to touch input
Check whether the function keys still respond, which would indicate the display is active but the touch layer is faulty. Inspect the screen surface for damage, contamination, or excessive pressure marks that may affect the resistive touch layer.
Clean the screen surface with a soft, dry cloth. Perform a touchscreen calibration via the panel's Start Center if the option is available. If calibration does not resolve the issue, the touch panel overlay may need to be replaced.
Project cannot be downloaded to the HMI from TIA Portal
Verify the PC and HMI are on the same network subnet and that the HMI IP address in TIA Portal matches the actual panel IP address. Check that no firewall on the PC is blocking TIA Portal communication. Confirm the HMI is in transfer mode or has remote transfer enabled.
Set the correct IP address in both TIA Portal and the HMI Start Center. Disable any PC firewall temporarily to test connectivity. Enable 'Remote Control' in the HMI runtime settings to allow downloads without manually switching to transfer mode.
HMI panel freezes or restarts unexpectedly during operation
Check the 24 V DC supply for voltage dips or instability under load, which can cause unexpected resets. Review the HMI event log in TIA Portal for recorded system events prior to the freeze. Check for project errors such as excessive tag polling rates or large screen object counts.
Install a regulated and adequately rated 24 V DC power supply. Optimize the project by reducing polling cycles and simplifying complex screens. Perform a firmware update on the panel if an updated version is available from Siemens support.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page