Siemens 6AV2124-0QC02-0AX1 SIMATIC HMI TP700 Comfort
€ 1.339,00 – € 3.600,00Price range: € 1.339,00 through € 3.600,00
The Siemens 6AV2124-0QC02-0AX1 is a 7-inch widescreen Touch Panel belonging to the SIMATIC HMI Comfort Panel series, manufactured by Siemens. It is designed for high-performance human-machine interface applications, providing operators with a robust and responsive touchscreen interface for monitoring and controlling industrial automation systems. This panel is part of the Comfort Panel generation, which represents Siemens' advanced HMI platform offering expanded functionality over the Basic and Advanced panel lines.
The TP700 Comfort features a 7-inch TFT widescreen display with a resolution of 800 x 480 pixels and 16 million colors, delivering clear and detailed visualization. It supports both PROFINET and MPI/PROFIBUS communication interfaces, enabling seamless integration into a wide range of Siemens and third-party control architectures. The panel includes 12 MB of user memory for project data, supports USB host and device ports, and offers an SD card slot for data logging and project transfer. It runs on the Windows CE operating system and is configured using Siemens TIA Portal (WinCC Comfort/Advanced).
The SIMATIC TP700 Comfort is widely deployed in manufacturing, process automation, packaging machinery, and material handling systems. Its widescreen format and high color depth make it suitable for complex graphical displays and trend visualization in industries such as automotive, food and beverage, pharmaceuticals, and water treatment. The panel's robust construction and wide operating temperature range make it reliable in demanding industrial environments.
Technical Specifications
| Display Size | 7 inch |
|---|---|
| Display Type | TFT widescreen |
| Display Resolution | 800 x 480 pixels |
| Display Colors | 16,777,216 (16 million) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 9 W |
| Communication Interface | PROFINET (RJ45), MPI/PROFIBUS DP (RS-422/RS-485), USB 2.0 (host and device) |
| Memory | 12 MB user memory |
| Storage Expansion | SD card slot |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Dimensions (W x H x D) | 214 x 158 x 46 mm |
| Panel Cutout | 197 x 141 mm |
| Certifications | CE, UL, cULus |
| Operating System | Windows CE |
| Configuration Software | TIA Portal WinCC Comfort/Advanced |
Common Error Codes & System Events
- Event ID: 10000
- Configuration error detected during project download or startup. The project data may be incompatible with the panel firmware version.
Verify that the WinCC project version matches the panel firmware. Update firmware via SD card or USB if necessary and re-download the project. - Event ID: 20000
- Communication connection to the PLC has been lost or cannot be established. The configured communication partner is not responding.
Check PROFINET or PROFIBUS cable connections and verify IP address or MPI/DP address settings. Confirm the PLC is powered and in RUN mode. - Event ID: 40000
- Tag read/write error. The HMI cannot access a configured PLC tag or data block address.
Verify the PLC program contains the referenced data block and address. Check that the data types in the HMI project match those in the PLC. - Event ID: 50000
- Insufficient memory for runtime operation. The user memory is nearly full or a memory allocation error has occurred.
Reduce the project size by removing unused screens, images, or data logs. Offload data logging to an SD card to free internal memory. - Event ID: 70000
- SD card error. The SD card inserted in the panel is not recognized, is full, or is write-protected.
Remove and reinsert the SD card. Verify the card is formatted as FAT32, is not write-protected, and has sufficient free space. - Event ID: 110000
- Firmware update error. The firmware update process was interrupted or the update file is invalid.
Restart the panel and retry the firmware update using a valid firmware file from the Siemens support portal, transferred via SD card or USB. - Event ID: 130000
- Backup or restore operation failed. The project backup or restore via SD card or USB could not be completed.
Ensure the storage medium has sufficient space and is not corrupted. Retry the backup/restore operation using a freshly formatted SD card.
Frequently Asked Questions
What communication interfaces are available on the 6AV2124-0QC02-0AX1?
The TP700 Comfort provides one PROFINET interface (RJ45), one combined MPI/PROFIBUS DP interface (RS-422/RS-485), and two USB 2.0 ports (one host, one device). It also includes an SD card slot for data storage and project transfer.
Which software is required to configure this HMI panel?
The 6AV2124-0QC02-0AX1 must be configured using Siemens TIA Portal with the WinCC Comfort or WinCC Advanced engineering software. Older SIMATIC WinCC flexible software is not compatible with Comfort Panel generation devices.
Is this panel compatible with Siemens S7-300 and S7-1500 PLCs?
Yes, the TP700 Comfort is compatible with S7-300 and S7-400 PLCs via MPI/PROFIBUS DP, and with S7-1200 and S7-1500 PLCs via PROFINET. Third-party PLCs can also be connected using available communication drivers.
What is the front panel protection rating of this unit?
The front panel of the 6AV2124-0QC02-0AX1 is rated IP65, making it protected against dust ingress and low-pressure water jets, suitable for installation in control cabinet doors exposed to washdown or dusty environments.
Can the panel operate from a standard 24 V DC supply?
Yes, the TP700 Comfort operates from a 24 V DC supply, which is standard in industrial control cabinets. Power consumption is approximately 9 W under typical operating conditions.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within the specified range and that the connector is fully seated.
Correct any supply voltage issues. If the supply is confirmed good and the display remains blank, the internal power supply or backlight inverter may have failed and the panel should be sent for repair or replacement.
Touchscreen does not respond or responds inaccurately to touch input
Check whether the touch issue is consistent across the entire screen or localized to specific areas. Attempt a touchscreen recalibration from the panel's Start Center or Control Panel menu.
Perform a touchscreen recalibration via the Start Center. If the issue persists, clean the screen surface and check for physical damage to the resistive touch layer. A damaged touch panel assembly will require hardware replacement.
HMI cannot establish communication with the PLC
Verify the PROFINET IP address settings on both the HMI and PLC. Check the Ethernet cable and switch connections. For PROFIBUS, verify the bus address and termination resistors at both ends of the cable.
Correct IP address or bus address mismatches in the TIA Portal project. Replace faulty cables or connectors. Ensure PROFIBUS termination is active only at the two physical ends of the bus segment.
Project download from TIA Portal fails or times out
Check the USB or PROFINET connection between the engineering PC and the panel. Verify that the panel is in transfer mode (accessible from the Start Center) and that no firewall is blocking the TIA Portal communication.
Switch the panel to transfer mode manually via the Start Center. Disable PC firewall temporarily during download. Ensure the TIA Portal version matches the panel firmware version; update firmware if necessary.
Panel repeatedly reboots or crashes during runtime
Check for overheating by verifying ambient temperature and ensuring ventilation slots are not blocked. Review the system event log on the panel for specific event IDs that may indicate the root cause.
Ensure the operating environment does not exceed 50 °C. If overheating is not the cause, reduce project complexity or memory usage. A persistent crash may indicate corrupted firmware or a hardware fault requiring panel servicing.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page